Operation CHARM: Car repair manuals for everyone.

Condenser To Evaporator Line




Condenser to Evaporator Line













Removal and Installation

1. Recover the refrigerant. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.

2. Remove the condenser outlet fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.

- To install, tighten to 15 Nm (133 lb-in).

3. Disconnect the evaporator core inlet fitting.
- Discard the O-ring seals.

4. Remove the condenser-to-evaporator line.

5. To install, reverse the removal procedure.
- Install a new gasket seal and O-ring seals.

- Lubricate the refrigerant system with the correct amount of clean PAG oil. For additional information, refer to Climate Control System - General Information and Diagnostics Refrigerant Oil Adding.

6. Evacuate, leak test and charge the refrigerant system. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.