Pinpoint Test G: DTC U0155:87
Remote Function Actuator (RFA) Module
Pinpoint Test G: DTC U0155:87
Normal Operation
- DTC U0155:87 (Lost Communication With Instrument Panel Cluster (IPC) Control Module: Missing Message)- sets when the RFA (Remote Function Actuator) module is missing messages from the IPC (Instrument Panel Cluster) over the Medium Speed Controller Area Network (MS-CAN).
This pinpoint test is intended to diagnose the following:
- Module communication
- IPC (Instrument Panel Cluster)
- RFA (Remote Function Actuator) module
PINPOINT TEST G : DTC U0155:87
G1 VERIFY CUSTOMER CONCERN
- Ignition ON.
- Verify that there is an observable symptom present.
Is an observable symptom present?
Yes
GO to G2.
No
The system is operating normally at this time. The DTC may have been set due to high network traffic or intermittent fault condition.
G2 CHECK THE COMMUNICATION NETWORK
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: Network Test.
- Carry out the network test.
Does the IPC (Instrument Panel Cluster) pass the network test?
Yes
GO to G3.
No
REFER to Information Bus.
G3 RECHECK THE RFA (Remote Function Actuator) MODULE DTCs
- Clear the DTCs. Repeat the RFA (Remote Function Actuator) module self-test.
Is DTC U0155:87 still present?
Yes
GO to G4.
No
The system is operating correctly at this time. The DTC may have been set due to high network traffic or intermittent fault condition.
G4 CHECK FOR DTC U0155 OR DTC U0155:87 IN OTHER MODULES
NOTE: If new modules were installed prior to the DTC being set, the module configuration may be incorrectly set during Programmable Module Installation (PMI) or the PMI (Programmable Module Installation) may not have been carried out.
- Clear all DTCs.
- Ignition OFF.
- Ignition ON.
- Wait 10 seconds.
- Enter the following diagnostic mode on the scan tool: Self-Test.
- Retrieve the continuous memory DTCs from all modules.
Is DTC U0155 or DTC U0155:87 set in any other module?
Yes
INSTALL a new IPC (Instrument Panel Cluster). TEST the system for normal operation.
No
INSTALL a new RFA (Remote Function Actuator) module. REFER to Remote Function Actuator (RFA) Module . TEST the system for normal operation.