Blower Motor: Service and Repair
Blower Motor
Removal and Installation
1. Remove the 3 RH lower instrument panel insulator screws and remove the insulator.
2. Disconnect the blower motor electrical connector.
3. Depress the 2 retaining tabs and detach the blower motor vent tube from the heater core and evaporator core housing.
4. NOTE: The blower motor vent tube must be completely detached from the heater core and evaporator core housing to allow the blower motor to be rotated.
Rotate the blower motor counterclockwise to detach it from the heater core and evaporator core housing and remove the blower motor.
5. To install, reverse the removal procedure.