Operation CHARM: Car repair manuals for everyone.

Air Cleaner Housing: Service and Repair




Air Cleaner Outlet Pipe

Removal and Installation

1. Disconnect the crankcase ventilation tube -to-Air Cleaner (ACL) outlet pipe quick connect coupling.

2. Loosen the ACL (Air Cleaner) outlet pipe-to-Throttle Body (TB) clamp.
- To install, tighten to 4 Nm (35 lb-in).


3. Loosen the ACL (Air Cleaner) outlet pipe-to-ACL (Air Cleaner) assembly clamp.
- Remove the ACL (Air Cleaner) outlet pipe.

- To install, tighten to 4 Nm (35 lb-in).


4. NOTE: The ACL (Air Cleaner) outlet pipe should be securely sealed to prevent unmetered air from entering the engine.
To install, reverse the removal procedure.