Engine - Rough Idle/No Start
Bulletin No.: 004/92Issued: 3/24/92
Revised: 4/7/92
Category
G
Applicable Model/s
1991 Navajo
Subject:
ROUGH IDLE/NO START
DESCRIPTION
A rough idle, no start or hard start condition may he caused by a faulty ground circuit in the Electronic Distributorless Ignition System (EDIS) module connector*
INSPECTION & REPAIR PROCEDURE*
1. Locate the EDIS module connector B-18 on the radiator Support.* Figure 1.
2. Locate the ground circuit wire (black wire with a white stripe) in module connector B-18.*
3. Check the terminal on the ground circuit wire. If the terminal does not have a brass sleeve, replace the ground circuit terminal by splicing in a new terminal assembly (ZZL0 67 371).
* The revised sections are indicated by an asterisk. Please replace the original bulletin with this revised bulletin.
PARTS INFORMATION
PART NUMBER DESCRIPTION
ZZL0 67 371 Terminal Assembly
WARRANTY INFORMATION
(applies to vehicles covered under warranty)
Warranty Type Code: A
Customer Comment Code: 01
Damage Code: 9V
Part No. of Main Cause: ZZL0 67 371
Operation No: YY0048RX
Labor Hour: 0.4 Hr.