Pinpoint Test 2
PINPOINT TEST 2: THE INDIVIDUAL REVERSING LAMP IS INOPERATIVEStep 1:
Normal Operation
When the transmission is placed in REVERSE, voltage is routed to the backup lamps through circuit (BR/Y). Ground for the backup lamps is provided through circuit (B/Y).
Possible Causes
- Circuit (BR/Y) open
- Circuit (B/Y) open
CAUTION: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.