EVAP Running Loss System Repair Verification Drive Cycle
EVAP Running Loss System Repair Verification Drive CycleNOTE: When the ambient air temperature outside is 4.4 to 37.8°C (40 to 100 °F), or the altitude is above 2438 meters (8000 feet), the EVAP monitor will not run.FLI PID must be between 15 and 85%.
1. Complete vehicle preparation.
2. Cruise at 72 to 104 km/h (45 to 65 mph) for 10 minutes (avoid sharp turns and hills).
3. To initiate the EVAP monitor, the EVAPPDC PID must increase to at least 75%(canister purge vent open). At this time, the EVAPCV PID will then display 100%(canister vent solenoid closed to seal the system) and the monitor will begin to run. Continue to drive at steady throttle with light steering until the EVAPCV displays 0%(canister vent solenoid open, system unsealed).
4. Bring the vehicle to a stop.
5. With the scan tool, view the EVAP monitor for completion through the On-Board System Readiness Tests Menu. Repeat Step 2 if the EVAP monitor is not complete.
6. Verify no DTCs are retrieved with exception of P1000.