Operation CHARM: Car repair manuals for everyone.

Battery - Drain Tests

Battery-Drain Tests

NOTE: No vehicle should have more than a 50 mA (0.050 amp) continuous draw.

Check for current drains on the battery in excess of 50 milliamps (0.050 amp) with all the electrical accessories off and the vehicle at rest. Current drains can be tested with the following procedure.

WARNING: Do not attempt this test on a lead-acid battery that has recently been recharged. Explosive gases can cause personal injury.

CAUTION: To prevent damage to the meter, do not crank the engine or operate accessories that draw more than 10 A.

NOTE: Many modules draw 10 mA (0.010 amp) or more continuously.

Use an in-line ammeter between the battery positive or negative post and its respective cable or an inductive ammeter.

NOTE: Typically, a drain of approximately one amp can be attributed to an engine compartment lamp, glove compartment lamp, or luggage compartment lamp staying on continually. Other component failures or wiring shorts may be located by selectively pulling fuses to pinpoint the location of the current drain. When the current drain is found, the meter reading will fall to an acceptable level. If the drain is still not located after checking all the fuses, it may be due to the generator.

1. Make sure the junction box/fuse panels are accessible without turning on interior and underhood lights.
2. Drive the vehicle at least five minutes and over 48 km/h (30 mph) to turn on and exercise vehicle systems.
3. Allow the vehicle to sit with the key off for at least 40 minutes to allow modules to time out/power down.
4. Connect a fused jumper wire between the negative battery cable and the negative battery post to prevent modules from resetting and to catch capacitive drains.
5. Disconnect the negative battery cable from the post without breaking the connection of the jumper wire.

NOTE: It is very important that continuity is not broken between the battery and the negative battery cable when connecting the meter. If this happens, the entire procedure must be repeated.

6. Connect the tester between the negative battery cable and the post. The meter must be capable of reading milliamps and should have a 10 amp capability.

NOTE: If the meter settings need to be switched or the test leads need to be moved to another jack, the jumper wire must be reinstalled to avoid breaking continuity.

7. Remove the jumper wire.

NOTE: Amperage draw will vary from vehicle to vehicle depending on the equipment package. Compare to a comparable vehicle for reference.

NOTE: No vehicle should have more than a 50 mA (0.050 amp) draw.

8. If the draw is found to be excessive, pull fuses from the battery/smart junction box one at a time and note the current drop. Do not reinstall the fuses until you are finished testing. When the current level drops to an acceptable level after removing a fuse, the circuit containing the excessive draw has been located.
9. Check the wiring schematic in the Mazda Truck Wiring Diagrams for any circuits that run from the battery without passing through the battery/smart junction box. Disconnect these circuits if the draw is still excessive. Also disconnect the generator electrical connections if the draw can not be located. The generator may ne internally shorted causing the current drain.