Wiper Switch: Testing and Inspection
Multifunction Switch Inspection
1. Remove the multifunction switch
2. Inspect for continuity between the multifunction switch terminals using an ohmmeter.
Lamp Portion
Lamp Portion:
Turn Signal, Hazard:
Wiper / Washer Portion
Wiper / Washer Portion:
Intermittent Wiper Circuit - Front:
3. If not as specified, replace the multifunction switch.