PID/Data Monitor Display
PID/DATA MONITOR DISPLAY1. Connect the MMDS to the DLC2 connector.
2. After the vehicle is identified, select the following items from the initialization screen of the MMDS.
- When using the IDS (notebook PC)
- Select the "Toolbox" tab.
- Select the "Data Logger".
- Select the "Module".
- Select the "EATC".
- When using the PDS (pocket PC)
- Select the "Module Tests".
- Select the "EATC".
- Select the "Data Logger".
3. Select the applicable PID from the PID table
4. Verify the PID data according to the directions on the screen.
NOTE: The PID data screen function is used for monitoring the calculated value. Therefore, if the monitored value of the output parts is not within the specification, inspection of the monitored value of input parts corresponding to applicable output part control is necessary. In addition, because the system does not display output part malfunction as abnormality in the monitored value, it is necessary to inspect the output part individually.