Fuel Pump Unit Inspection
FUEL PUMP UNIT INSPECTION [L3 WITH TC]
Continuity Inspection
NOTE:
- Perform the following test only when directed.
1. Disconnect the negative battery cable.
2. Remove the rear seat cushion.
3. Remove the service hole cover.
4. Disconnect the fuel pump unit connector.
5. Inspect for continuity between fuel pump unit connector terminals B and D.
- If there is no continuity, replace the fuel pump body.
- If as specified, carry out the "Circuit Open/Short Inspection".
Circuit Open/Short Inspection
1. Inspect the following wiring harnesses as for open or short circuit (continuity check).
Open circuit
- If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
- Fuel pump unit terminal B and fuel pump relay terminal A
- Fuel pump unit terminal D and body ground
Short circuit
- If there is continuity, there is a short circuit. Repair or replace the wiring harness.
- Fuel pump unit terminal B and power supply
- Fuel pump unit terminal B and body ground
- Fuel pump unit terminal D and power supply
Fuel Pump Hold Pressure Inspection
WARNING:
- Fuel line spills and leakage are dangerous. Fuel can ignite and cause serious injuries or death and damage. Always carry out the following procedure with the engine stopped.
CAUTION:
- Disconnecting/connecting the quick release connector without cleaning it may cause damage to the fuel pipe and quick release connector. Always clean the quick release connector joint area before disconnecting/connecting using a cloth or soft brush, and make sure that it is free of foreign material.
NOTE:
- Perform the following test only when directed.
1. Complete the "BEFORE SERVICE PRECAUTION". (See Before Service Precaution.)
2. Disconnect the negative battery cable.
3. Remove the battery and battery tray.
CAUTION:
- The quick release connector may be damaged if the tab is bent excessively. Do not expand the tab over the stopper.
4. Disconnect the quick release connector from the fuel tank. (See Service and Repair.)
5. Turn the lever 90° against the hose of the SST to plug the SST outlet.
6. Push the SST quick release connector into the fuel pipe until a click is heard.
7. Set the fuel hose into a container to avoid fuel spills.
8. Start the fuel pump using the following procedure.
Using M-MDS
1 Connect the negative battery cable.
2 Connect the M-MDS to the DLC-2.
3 Using the simulation function "FP", start the fuel pump.
Without using M-MDS
1 Remove the fuel pump relay.
CAUTION:
- Short the specified terminals because shorting the wrong terminal of the main fuse block may cause malfunctions.
2 Using a jumper wire, short fuel pump relay terminals C and D in the main fuse block.
3 Connect the negative battery cable and operate the fuel pump.
9. Turn the ignition switch to the LOCK position.
10. Measure the fuel pump hold pressure after 5 min.
- If not as specified, replace the fuel pump after inspecting the following:
- Fuel line for clogging or leakage
Fuel pump hold pressure
- More than 230 kPa {2.3 kgf/cm2, 33 psi}
11. Disconnect the jumper wire.
12. Disconnect the SST.
13. Connect the quick release connector. (See Service and Repair.)