Input/Turbine Speed Sensor Inspection
INPUT/TURBINE SPEED SENSOR INSPECTION [AW6A-EL, AW6AX-EL]
On-Vehicle Inspection
CAUTION:
- Water or foreign material entering the connector can cause a poor connection or corrosion. Be sure not to allow water or foreign material on the connector when disconnecting.
- Do not damage the terminals.
1. Disconnect the negative battery cable.
2. Remove the air cleaner component. Service and Repair
3. Remove the TCM. Service and Repair
4. Verify that there is no continuity between the coupler component terminals B12 and GND or B13 and GND.
- If there is any malfunction, inspect the coupler component.
- If the coupler component is normal, perform an off-vehicle inspection of input/turbine speed sensor.
NOTE:
- Inspect with a tester that can indicate more than 10 megohms and confirm that the value is more than 1 megohm.
5. Verify that there is continuity between coupler component terminals B12 and B13.
- If there is any malfunction, inspect the coupler component.
- If the coupler component is normal, replace the input/turbine speed sensor. Input/Turbine Speed Sensor Removal/Installation
6. Install the TCM. Service and Repair
7. Install the air cleaner component. Service and Repair
8. Connect the negative battery cable.
Off-Vehicle Inspection
WARNING:
- A hot transaxle and ATF can cause severe burns. Turn off the engine and wait until they are cool before replacing the ATF.
CAUTION:
- Water or foreign material entering the connector can cause a poor connection or corrosion. Be sure not to allow water or foreign material on the connector when disconnecting.
- Do not damage the terminals.
1. Disconnect the negative battery cable.
2. Remove the air cleaner component. Service and Repair
3. Remove the under cover.
4. Drain the ATF. Automatic Transaxle Fluid (ATF) Replacement
5. Remove the resonance chamber. Service and Repair
6. Remove the thermo valve. Removal and Replacement
7. Remove the control valve body. Removal and Replacement
8. Remove the input/turbine speed sensor. Input/Turbine Speed Sensor Removal/Installation
9. Connect the input/turbine speed sensor terminal 2 to the battery positive terminal, connect the battery negative terminal to input/turbine speed sensor terminal 1 through an ammeter set to a resistance of 100 ohm.
10. Measure the current while waving a magnet back and forth over the top of the input/turbine speed sensor (less than 5 mm {0.197 in}).
- If there is any malfunction, replace the input/turbine speed sensor. Input/Turbine Speed Sensor Removal/Installation
Input/turbine speed sensor
11. Install the input/turbine speed sensor. Input/Turbine Speed Sensor Removal/Installation
12. Install the control valve body. Removal and Replacement
13. Install the thermo valve. Removal and Replacement
14. Install the resonance chamber. Service and Repair
15. Add ATF to the specified level. Automatic Transaxle Fluid (ATF) Replacement
16. Install the under cover.
17. Install the air cleaner component. Service and Repair
18. Connect the negative battery cable.
19. Perform the mechanical system test. Mechanical System Test