Operation CHARM: Car repair manuals for everyone.

Keyless Entry: Service and Repair




SECURITY ACCESS PROCEDURE

1. Connect the M-MDS to DLC-2.






2. After the vehicle is identified, select the following items from the initial screen of the M-MDS.

- When using the IDS (laptop PC)

- Select the "Body".
- Select the "Security".
- Select the "PATS Functions".

- When using the PDS (Pocket PC)

- Select the "All Tests and Calibrations".
- Select the "PATS Functions".

3. Then, select an item from the screen menu.

- "Program Additional Advanced Key"
- "Advanced Key Code Erase and Program"
- "Steering Lock Unit Programming"
- "Program Additional Ignition Key"
- "Ignition Key Code Erase and Program"
- "Customer Spare Key Programming Enable"
- "Customer Spare Key Programming Disable"
- "Parameter Reset"

4. The security access begins and the M-MDS displays "OUT-CODE".
NOTE:
- When "OUT-CODE" is first displayed, turning the ignition switch from the LOCK to the ON position 5 times will change the "OUT-CODE".

5. Input the "IN-CODE" that corresponds to the "OUT-CODE" displayed on the M-MDS screen.

6. Perform the procedure according to the directions on the screen.