TCM Inspection - AW6A-EL, AW6AX-EL
TCM INSPECTION [AW6A-EL, AW6AX-EL]
Control Module Inspection
1. Remove the air cleaner component. Service and Repair
2. Measure the voltage at each TCM connector (wiring harness-side) terminal and refer to the terminal voltage table.
- If the voltage is not as specified in the Terminal Voltage Table (Reference), inspect the parts under "Inspection item (s)".
WARNING:
- Be careful not to damage the connector waterproofing when measuring the TCM terminal voltage. If damaged, the waterproofing efficiency could be negatively affected.
NOTE:
- Use the ground of terminal A9 of the TCM connector (wiring harness-side) when measuring terminal voltage, as an error may occur when connecting the negative circuit tester to ground.
Terminal Voltage Table (Reference)
Terminal Voltage Table (Reference):
3. Remove the TCM. (See TCM Removal/Installation - AW6A-EL, AW6AX-EL.)
4. Verify that continuity or resistance at terminal is as indicated in the terminal continuity/resistance table.
- If there is any malfunction, inspect the parts under "Inspection item (s)".
- If the system does not work properly even though the parts or related wiring harnesses do not have any malfunction, replace the TCM. TCM Removal/Installation - AW6A-EL, AW6AX-EL
Terminal Continuity/Resistance Table (Reference)
Terminal Continuity/Resistance Table (Reference) (Part 1):
Terminal Continuity/Resistance Table (Reference) (Part 2):
Terminal Continuity/Resistance Table (Reference) (Part 3):
5. Perform the neutral position learning. Programming and Relearning