Adjustment With Ohmmeter
Fig. 5 Throttle Switch Inspection:
Fig. 21 Inserting thickness gauge.:
1. Disconnect connector from throttle sensor and connect ohmmeter to center and bottom terminals (TL & IDL).
2. Insert .02 inch thickness gage between throttle stop screw and stop lever Fig. 21.
3. Loosen two throttle sensor attaching screws.
Fig. 23 Rotating throttle sensor.:
4. Rotate throttle position sensor clockwise approximately 30°, then rotate it back counterclockwise until continuity exist Fig. 23.
Fig. 22 Thickness gauge chart.:
5. Replace thickness gage with .027 inch gage and ensure continuity does not exist Fig. 22. If continuity exist, repeat steps 3 and 4.
6. Tighten two attaching screws. Be careful not to move throttle sensor from set position when tightening screws.
7. Open throttle valve fully a few times, then recheck adjustment.