A/C - Installation Updates
88mazda01Category Applicable Model/s Subject Bulletin No. 026/88
16 1988 626/MX-6 AIR CONDITIONER INSTALLATION Issued 2/5/88
Revised
DESCRIPTION
Please note the following 3 subjects when installing or servicing 1988 626/MX-6 air conditioner systems.
SUBJECT 1: Relocation of Ground Strap
Effective immediately, relocating the O.E.M. ground wire as shown in the A/C installation instructions is no longer required. Instead, follow the new installation procedures shown below.
This alteration is to eliminate the possibility of the ground wire interfering with surrounding parts.
The A/C installation instructions will be revised in the near future and will reflect this change.
O.E.M.: Original Equipment from Manufacturer
New installation procedure:
SUBJECT 2: Installation of Plastic Pin on Blower Motor
During installation of air conditioning, be sure to reinstall the plastic pin (shown in the illustration below) back into the metal clip hole.
The pin must be installed because there is a possibility that the seal plate could be installed too close to the evaporator, which may cause the seal plate not to cover the hole completely.
SUBJECT 3: Cooler Pipe #2 Modification
The refrigerant charge valve on the cooler pipe #2 (suction side) has been eliminated since October 1987 production.
When servicing the A/C system, use the service valve which is located on the compressor.