Air Flow Meter/Sensor: Testing and Inspection
Air Flow Meter Removal:
1. Disconnect the air flow meter connector.
2. Remove the air hose to the air pump.
3. Loosen the air funnel bolt.
4. Remove the air cleaner and the air flow meter.
5. Remove the air flow meter.
6. Inspect the air flow meter body for cracks or damage.
7. Verify that the measuring plate opens smoothly.
Air Flow Meter Schematic:
8. Measure the resistance of the air flow meter using an ohmmeter and compare the readings to the chart below.