Oxygen Sensor: Description and Operation
Oxygen Sensor:
Oxygen Sensor Operation:
^ The oxygen sensor generates voltage according to exhaust gas oxygen content.
^ It incorporates a platinum coated ceramic zirconia tube which generates voltage if there is a difference in oxygen concentration between the inside and outside of the tube.
^ Voltage range is approximately 0.1 - 1.0V. Voltage increases when oxygen content is low (rich) and decreases when oxygen content is high (lean).
^ The ECU determines air/fuel ratio based on the voltage generated and makes appropriate adjustments to maintain the optimum ratio of 14.7:1. The difference in oxygen concentration changes greatly in the area of optimum air/fuel ratio, resulting in large voltage changes that are easily calculated by the ECU.
^ To operate at peak efficiency, sensor must heat up to approximately 572 - 752°F (300 - 400°C).