Thermoswitch
1. Remove switch and place in water with a thermometer. Heat slowly.2. Measure resistance across terminals as water temperature increases. Resistance should be as follows:
25 - 35 ohms @ 68°F (20°C)
64 - 76 ohms @ 176°F (80°C)