Operation CHARM: Car repair manuals for everyone.

Thermoswitch

1. Remove switch and place in water with a thermometer. Heat slowly.
2. Measure resistance across terminals as water temperature increases. Resistance should be as follows:

25 - 35 ohms @ 68°F (20°C)
64 - 76 ohms @ 176°F (80°C)

3. If not as specified, replace switch.