Fuel System Priming
Priming The Fuel System
After releasing the fuel pressure for repairs or inspection, the system must be primed to avoid excessive cranking when first starting the engine.
Procedure
1. Connect the diagnosis connector terminals F/P and GND with a jumper wire.
2. Turn the ignition switch ON for Approximately 10 seconds and check for fuel leaks.
3. Turn the ignition switch OFF and remove the jumper wire.