Automatic Transaxle
OUTPUT VOLTAGEFunction Sensor Output Voltage:
1. Connect SST, or equivalent, as shown.
2. Connect vacuum pump to EGR control valve.
3. Turn ignition "ON." Measure voltage as shown on table.
4. If not correct at terminal 27, check wiring harness and PCM terminal 26.
RESISTANCE
Function Sensor Resistance:
1. Unplug sensor and connect ohmmeter.
2. Connect vacuum pump to EGR control valve.
3. Measure resistance between terminals with vacuum applied as shown.
4. If not as specified, replace EGR control valve.