With Automatic Transaxle (ATX)
1. Measure voltage at each PCME terminal listed below. Refer to Computers and Control Systems.^ 4 (ignition control module)
^ 50 (mass airflow sensor)
^ 24 (crankshaft position sensor)
2. Check condition of connector, distributor, ignition coil, and high tension leads.
3. If all are normal, but misfire still occurs, replace ignition control module.