Solenoid Valve-Turbo Precontrol
Removal/Installation
1. Remove in the order shown in the figure.
2. Install in the reverse order of removal.
1. Pressure chamber
2. Connectors
3. Vacuum hoses
4. Solenoid Valve-Turbo Precontrol
5. Solenoid Valve-Wastegate Control
Inspection
1. Remove the solenoid valve.
2. Blow through the solenoid valve from hose A and check that air does not flow from B to A.
3. Apply battery positive voltage to solenoid valve and check that air does flow the solenoid valve from A to B.
4. If not as specified, measure the resistance.
Resistance: 29-33 ohms 20°C (68°F)