Oxygen Sensor: Service and Repair
Removal- Disconnect harness terminal.
- Remove sensor with suitable socket or wrench.
Installation
- Apply thin coating of anti-seize compound to threads.
NOTE: Do not contaminate sensing tip with compound.
- Install sensor and torque to 29 - 49 Nm (22 - 36 ft.lb.).