Heated Oxygen Sensor Heater
Inspection1. Disconnect the heated oxygen sensor connector.
2. Measure the resistance between heated oxygen sensor terminals B and C [Front] (D and C [Rear]) by using an ohmmeter.
Specification: Approx. 6 ohms [20 °C {68 °F}]
3. If not as specified, replace the heated oxygen sensor.