Operation CHARM: Car repair manuals for everyone.

Barometric Pressure Sensor: Specifications

Barometric Pressure Side Voltage Measured At PCM terminal 3H:
EGR Boost Signal Side Voltage Measured At PCM terminal 3N:

Barometric Pressure 101.3 kPa (29.9 in Hg) Approx. 4.0 Volts
A 20 kPa (5.9 in Hg) vacuum applied
B 43 kPa (12.7 in Hg) vacuum applied
Variation Between A and B Approx. 1.5 Volts