Variable Induction Control Actuator: Testing and Inspection
VRIS Actuator Testing:
VRIS SHUTTER VALVE ACTUATOR (No.1, No.2) INSPECTION
1. Disconnect the vacuum hose from the shutter valve actuator.
2. Connect a vacuum pump to the actuator.
3. Apply vacuum and verify that the rod is pulled into the actuator.