Oxygen Sensor Relay: Testing and Inspection
HEATED OXYGEN SENSOR HEATER RELAYInspection
1. Remove the heated oxygen sensor heater relay.
2. Apply battery positive voltage and check continuity between terminals of the relay by using ohmmeter.
3. If not as specified, replace the heated oxygen sensor heater relay.