Oxygen Sensor Heater Inspection
Oxygen Sensor Heater Inspection1. Disconnect the heated oxygen sensor connector.
2. Measure the resistance between heated oxygen sensor terminals B and C by using an ohmmeter.
Specification: Approx. 6 Ohms 20°C (68°F)
3. If not as specified, replace the heated oxygen sensor.
Tightening torque: 30-49 Nm (22-36 ft.lb.)