Operation CHARM: Car repair manuals for everyone.

Malfunction Indicator Lamp - A/T: Testing and Inspection


HOLD INDICATOR LIGHT
Inspection of operation
1. Turn the ignition switch from OFF to ON.

NOTE: The HOLD indicator light will flash if a malfunction exists in any of the EC-AT system components.




2. Verify that the HOLD indicator light is not illuminated.
3. Depress the switch and verify that the HOLD indicator light illuminates.
4. If the HOLD switch function is not as specified, check the HOLD switch, and then check the terminal voltage of the HOLD indicator light.

Inspection of voltage
1. Remove the instrument cluster.
2. Turn the ignition switch to ON.







3. Measure the voltage between terminal 2G and a ground.

Inspection of continuity
1. Disconnect the negative battery cable.
2. Disconnect the instrument cluster connector.
3. Check for continuity between terminal 2F and the transaxle control module terminal 1 K.







4. If not correct, check the wiring harness (instrument cluster-transaxle control module).
5. If correct, go to the next step.
6. Check for continuity between terminals 2G and 2F.







7. If not correct, replace the instrument cluster or bulb.
8. Install the instrument cluster.
9. Connect the negative battery cable.