With SST-New Generation Star Tester (Data Monitor)
1. In the passenger compartment, connect the Special Service Tools New Generation Star (NGS) tester to the data link connector-2 as shown in the figure.
2. Select the "PID DATA MONITOR AND RECORD" and press TRIGGER.
NOTE: The "PID/DATA MONITOR AND RECORD" function is to monitor the calculation value of input/output signals in the PCM. Deviation in the value does not always indicate malfunction in the related input/output devices (sensors and solenoids).
3. Press CLEAR to clear previously select items. (A list of item descriptions appears on the screen.)
4. Select items necessary and press START.
5. Carry out inspection referring to PID/DATA MONITOR table.
6. If normal output signal cannot be detected when all input signals are normal, replace the PCM.
PID/DATA MONITOR TABLE