Operation CHARM: Car repair manuals for everyone.

Ignition Cable: Testing and Inspection

HIGH-TENSION LEAD INSPECTION
1. Measure the resistance of the high-tension leads.

Specification: 16kohms per 1.00m (3.28ft) @ 20°C (68°F)

2. If not as specified, replace the high-tension lead.