Fuel Pump Fuel Hold Pressure
WARNING: Fuel line spills and leaks are dangerous. Fuel can ignite and cause serious injuries or death and damage. Fuel can also irritate skin and eyes. To prevent this, always complete the "Fuel Pressure Release Procedure".Fuel Pressure Release
1. Disconnect the negative battery cable.
2. Connect a fuel pressure gauge to the fuel pump and plug the outlet of the gauge as shown. (Install clamps as shown.)
3. Connect the negative battery cable.
4. Connect data link connector terminals F/P and GND by using a jumper wire.
5. Turn the ignition switch to ON for approx. 10 sec. to operate the fuel pump.
6. Turn off the ignition switch. Wait for 5 min., and observe the fuel pressure.
Pressure: More than 150 kPa (21 psi)
7. Disconnect the jumper wire.
8. If not as specified, replace the fuel pump.