1998-2000 Millenia
1998-2000 Millenia1. Dry the evaporator using the following procedure:
WARNING:
Running the engine inside an enclosed area, such as a garage, is dangerous. Exhaust gas, which contains poisonous carbon monoxide, could easily enter the cabin. Loss of consciousness or even death could occur. Don't run the engine when inside an enclosed area.
A. Start the engine.
B. Set the HVAC controls as follows:
^ RECIRCULATE
^ FULL HEAT (display indicates 90°F)
^ FAN HIGH
^ A/C OFF (
^ AIRFLOW (FACE)
NOTE:
There are three A/C positions on the LCD panel (A/C, A/C econ,
C. Open one window approximately one half inch.
D. Let the engine run for 15 minutes.
2. Remove the glove box by removing the two (2) screws on the bottom of the glove box assembly.
3. Shake a bottle of Mazda Cooling Coil Coating well and attach it to the applicator, then connect the applicator to compressed shop air.
4. Insert the applicator through the right side the glove box guide into the grille of the recirculation door. Point the nozzle tip downwards and towards the center (approximately 7 o'clock position).
5. Spray the entire contents of the bottle in short bursts, 3 seconds ON, 3 seconds OFF into the rotating fan. A fine mist may exit from the ducts.
6. When the bottle is empty, stop the engine and remove the applicator.
NOTE:
For reuse, clean the applicator by flushing a bottle of clean water through it.
7. Use STEP 1 to dry and cure the product.
8. While the product is drying, re-install the glove box.
9. Note application date in service record.