Operation CHARM: Car repair manuals for everyone.

Charging System: Specifications

Charging System Specifications
Battery
Test Load Chart
Battery Load (A)
GROUP 36R 240
Battery Positive Voltage With Load
Approximate Battery Temperature Minimum Voltage (V)
21 degrees C (70 degrees F) 9.6
15 degrees C (60 degrees F) 9.5
10 degrees C (50 degrees F) 9.4
4 degrees C (40 degrees F) 9.3
-1 degrees C (30 degrees F) 9.1
-7 degrees C (20 degrees F) 8.9
-12 degrees C (10 degrees F) 8.7
-18 degrees C (0 degrees F) 8.5
Dark Current 20 mA Max.
Charging Current
Battery Type (5 Hour Rate) Slow Charge (A) Quick Charge (A)
GROUP 36R (48) 4.5-5.5 30
Battery Positive Voltage After Charge Above 12.4 V
Generator
Standard Voltage
Terminal Ignition Switch: ON Idle (V)
At 20 degrees C (68 degrees F).
B B+ 14.1-14.7 V
L Approximately 1 V 13.2-13.8 V
S B+ 14.1-14.7 V
Standard Current (Referance)
Engine Speed (RPM) Terminal B Current (A)
1,000 Approximately 70 or below
Must not be 0.
2,000 Approximately 90 or below
Must not be 0.