Interior Lighting Relay
>>
Testing and Inspection
Interior Lighting Relay: Testing and Inspection
1.
Disconnect the negative battery cable.
2.
Remove the TNS relay.
3.
inspect for continuity between the TNS relay terminals by using an ohmmeter.
4.
If not as specified, replace the TNS relay.