Operation CHARM: Car repair manuals for everyone.

EGR Boost Sensor: Testing and Inspection

NOTE
- The following vacuum values are indicated by relative pressure from atmospheric pressure.




1. Connect the SSTs (NGS) to the data link connector-2.
2. Select the "PID/DATA MONITOR AND RECORD" function on the NGS display.
3. Select "BARO V" on the NGS display and press START. The NGS measures and shows the voltage.
4. Turn the ignition switch to ON.

CAUTION
- Do not apply a vacuum outside of the 8peclfied limits. Doing so will damage the EGR boost sensor.

5. Apply vacuum to the EGR boost sensor according to the following procedure.




6. increase the applied vacuum from 0 kPa {0 mmHg, 0 inHg} to -81.3 kPa {-610 mmHg, -24.0 inHg} and verify that the "BARO V" voltage decreases accordingly.

Reference data

NOTE
- The output voltage varies with the measure condition.

Measuring condition
- Input voltage: 5.0 V
- Atmospheric pressure: 101.3 kPa {760 mmHg, 29.9 inHg}
- Outside temperature: 25°C {77°F}




7. if not as specified, perform the following inspection.
(1) Harness continuity
- Between PCM terminal 3F and EGR boost sensor terminal A
- Between PCM terminal 3AB and EGR boost sensor terminal B
- Between PCM terminal 3A and EGR boost sensor terminal C
(2) Terminal voltage (Ignition switch ON)
- EGR boost sensor terminal B voltage: Ground (Below 1.0 V)
- EGR boost sensor terminal C voltage: Constant voltage (4.5 - 5.5 V)




8. If terminal voltage is correct and if there is harness continuity, replace the EGR boost sensor.