Alternator
Generator SpecificationsVoltage at Terminal L | ||
Ignition Switch: ON | Approximately 1.0 V | |
Idle | 13.0-14.0 V | |
Standard Voltage | ||
Terminal | Ignition Switch: ON | Idle |
B | B+ Battery Positive Voltage. | B+ Battery Positive Voltage. |
L | Approximately 1.0 V | Approximately 1.0 V less than Battery Voltage |
S | B+ Battery Positive Voltage. | B+ Battery Positive Voltage. |
IG | B+ Battery Positive Voltage. | B+ Battery Positive Voltage. |
Standard Current (Referance) | ||
Electrical Load Values are measure with the battery fully charged. As the battery discharges the current becomes greater. | Idle | 2,000 RPM |
OFF | Approximately 14 A | Approximately 15 A |
ON Turn ON the following electrical systems: Headlights (High Beam). Brake light. Cooling Fan. Condenser Fan | Approximately 70 A | Approximately 81 A |