Automatic Transmission/Transaxle: Service Precautions
CONNECTORSDisconnecting Connectors
^ When disconnecting two connectors, grasp the connectors, not the wires.
^ Connectors can be disconnected by pressing or pulling the lock lever as shown.
Locking Connector
^ When locking connectors, listen for a click that will indicate they are securely locked.
Inspection
1. When a tester is used to check for continuity or to measure voltage, insert the tester probe from the wiring harness side.
2. Check the terminals of waterproof connectors from the connector side, as they cannot be accessed from the wiring harness side.
Caution
^ To prevent damage to the terminal, wrap a thin wire around the lead before inserting it into the terminal.