Daytime Running Lamp Control Unit: Testing and Inspection
Terminal Voltage List (Reference): Connector View:
Terminal Voltage List (Reference): Pinouts (Part 1 Of 3):
Terminal Voltage List (Reference): Pinouts (Part 2 Of 3):
Terminal Voltage List (Reference): Pinouts (Part 3 Of 3):
1. Measure the voltage at the DRL control module terminals as indicated.
2. Disconnect the DRL control module connector before inspecting for continuity at terminal 1E.
- If not as specified, inspect the parts listed under "Action" and the related wiring harnesses.
- If the parts and wiring harnesses are okay but the system still does not work properly, replace the DRL control module.