Power Door Lock Control Module: Testing and Inspection
1. Remove the door lock control module from its support bracket.2. Disconnect the door lock control module connector.
Unlock All Door Types:
Unlock Only Driver's Side Type:
3. Inspect for continuity between the terminals of the door lock control module connector.
4. Reconnect the door lock control module connector.
Unlock All Door Types:
Unlock Only Driver's Side Type:
Unlock All Door Types:
Unlock Only Drivers Side Type:
5. Measure the voltage at the terminals of the door lock control module connector with the following terminals connected to GND.
- If not as specified, replace the door lock control module.