Active Command Modes Procedure
Active Command Modes ProcedureNote When driving the ABS motor and each valve forcibly, turn VPWR RLY on, and then each command on. VPWR RLY regulates the power supply for the ABS motor and eight valves.
1. Perform the New Generation Star (NGS) tester hook-up procedure.
2. Perform Steps 1 through 9 from the DTCs reading procedure.
3. Turn the ignition key to ON (engine oft or start engine. Move the cursor to ACTIVE COMMAND MODES. Press the TRIGGER key to enter this selection.
4. Move the cursor to ABS OUTPUT CONTROL. Press the TRIGGER key to enter this selection.
5. Move the cursor to command. Press the TRIGGER key to enter this selection.