Refrigerant Pressure Check
1. Install the manifold gauge set.2. Open the bonnet.
3. Close all the doors and all the windows.
4. Warm up the engine and run it at a constant 1,500 rpm.
5. Turn the switch on.
6. Set the temperature setting dial to 18.0 °C {64 °F}.
7. Measure the ambient temperature and the high- and low-pressure side readings of the manifold gauge.
- If the high- and low-pressure side readings are in the shaded zone shown in the figure, the refrigerant system is normal.
- If the pressure is abnormal, see flowchart No.20 and troubleshoot the system.