Continuity Inspection

1. Remove the service hole cover. (See FUEL FILTER (HIGH-PRESSURE) REMOVAL/INSTALLATION.)




2. Disconnect the fuel pump connector.
3. Inspect for continuity between fuel pump connector terminals B and D using an ohmmeter.
- If there is no continuity, replace the fuel pump.