Transmission Position Sensor/Switch: Adjustments
TRANSAXLE RANGE (TR) SWITCH ADJUSTMENT [GF4A-EL]1. Disconnect the negative battery cable.
2. Remove the air cleaner component.
3. Remove the nut and clip, and disconnect the selector cable.
4. Rotate the manual shaft to the N position.
5. Disconnect the TR switch connector.
6. Loosen the TR switch mounting bolts.
7. Connect an ohmmeter between terminals A and H.
8. Adjust the switch to the point where there is continuity between the terminals.
9. Tighten the TR switch mounting bolts.
Tightening torque
7.9 - 10.7 Nm (80 - 110 kgf.cm, 69.5 - 95.4 inch lbs.)
10. Verify that the selector lever range position and TR switch are aligned.
11. Connect the TR switch connector.
12. Connect the selector cable and install the nut and clip.
13. Install the air cleaner component.