Using Vacuum Pump
Whole system inspection1. Disconnect the vacuum hose between the purge solenoid valve and the catch tank from the purge solenoid valve.
2. Insert hose on the vacuum pump.
3. Connect the NGS tester to the DLC-2.
4. Turn the ignition key to ON.
5. Select the GENERIC OBD II FUNCTIONS and press TRIGGER.
6. Press Number 8 under CONT to continue the GENERIC OBD II FUNCTIONS.
NOTE:
- The following conditions cancel the ON BOARD DEVICE CONTROL function:
1. Ten minutes after TRIGGER on the NGS tester is depressed.
2. When engine is started.
3. If the pressure in the evaporative emission control system exceeds 6.43 kPa {48.26 mmHg, 1.9 inHg}.
- Therefore, the following tests, Step 7 through 15, should be conducted under the following conditions.
1. Within 10 minutes after TRIGGER on the NGS tester is depressed.
2. Without starting the engine.
7. Turn the menu dial clockwise or counterclockwise to highlight the ON BOARD DEVICE CONTROL and press TRIGGER.
8. Press CANCEL two times.
9. Select the DIAGNOSTIC DATA LINK and press TRIGGER.
10. Select the PCM - POWERTRAIN CONTROL MODULE and press TRIGGER.
11. Select the PID/DATA MONITOR AND RECORD and press TRIGGER.
12. Press the Number 5 under CLEAR to clear previously selected PIDs.
13. Turn the menu dial clockwise or counterclockwise to highlight the FTP and press TRIGGER.
14. Press the Number 7 under START to view PIDs.
15. Apply 1.7 kPa {13 mmHg, 0.5 inHg} vacuum. Vacuum should hold at the specified readings for a minimum of 2 minutes.
- If the FTP value does not hold, inspect the FTP sensor.
- If the FTP sensor is okay, carry out the "Inspection from charcoal canister to fuel tank."
Inspection from charcoal canister to fuel tank
1. Inspect for loose and wrongly connected hoses between the charcoal canister and the fuel tank. (See EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM STRUCTURAL VIEW.)
2. Disconnect the vacuum hose between the charcoal canister and the pressure control valve from the charcoal canister.
3. Insert hose on the vacuum pump.
4. Connect the NGS tester to the DLC-2.
5. Turn the ignition key to ON.
6. Select the GENERIC OBD II FUNCTIONS and press TRIGGER.
7. Press Number 8 under CONT to continue the GENERIC OBD II FUNCTIONS.
NOTE:
- The following conditions cancel the ON BOARD DEVICE CONTROL function:
1. Ten minutes after TRIGGER on the NGS tester is depressed.
2. When engine is started.
3. If the pressure in the evaporative emission control system exceeds 6.43 kPa {48.26 mmHg, 1.9 inHg}.
- Therefore, the following tests, Steps 8 through 16, should be conducted under the following conditions.
1. Within 10 minutes after TRIGGER on the NGS tester is depressed.
2. ignition key is at ON, but engine is not started.
8. Turn the menu dial clockwise or counterclockwise to highlight the ON BOARD DEVICE CONTROL and press TRIGGER.
9. Press CANCEL two times.
10. Select the DIAGNOSTIC DATA LINK and press TRIGGER.
11. Select the PCM - POWERTRAIN CONTROL MODULE and press TRIGGER.
12. Select the PID/DATA MONITOR AND RECORD and press TRIGGER.
13. Press the Number 5 under CLEAR to clear previously selected PIDs.
14. Turn the menu dial clockwise or counterclockwise to highlight the FTP and press TRIGGER.
15. Press the Number 7 under START to view PIDs.
16. Apply 1.7 kPa {13 mmHg, 0.5 inHg} vacuum. Vacuum should hold at the specified readings for a minimum of 2 minutes.
- If the FTP value does not hold, inspect the pressure control valve for damage and air leakage.
- If the pressure control valve is okay, carry out the "Inspection from charcoal canister to purge solenoid valve."
Inspection from charcoal canister to purge solenoid valve
1. Inspect for loose and wrongly connected hoses between the charcoal canister and the purge solenoid valve. (See EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM STRUCTURAL VIEW.)
2. Disconnect the vacuum hose between the charcoal canister and the catch tank from the charcoal canister.
3. Insert hose on the vacuum pump.
4. Apply 3.3 kPa {25 mmHg, 1.0 inHg} vacuum. Vacuum should hold at the specified readings for a minimum of 2 minutes.
- If the vacuum does not hold, inspect the following:
- Catch tank for plugging, damages and pinhole using vacuum pump
- Purge solenoid valve
- Charcoal canister for damage and pinhole
- CDCV for damage and leakage
- Detached, incorrectly installed or cracked hose from charcoal canister to CDCV