Cooling Fan Control Inspection
Cooling Fan Operation:
Cooling fan relay
1. Verify the engine is cold.
2. Turn the ignition key to ON.
3. Verify that the cooling fan is not operating.
- If the cooling fan is operating, go to the next step
4. Connect the SSTs (NGS tester) to the DLC-2.
5. Select the SIMULATION TEST function on the NGS display.
6. Select IG ON TEST mode.
7. Select FAN 3 PID.
8. Send OFF and verify the cooling fan is off.
- If the cooling fan is on, inspect for the following.
- Cooling fan relay is stuck in closed position.
- Short to GND circuit between cooling fan relay and PCM terminal 47
- Short to power in circuit at cooling fan relay
- DTC for ECT sensor (P0117, P0118, P0125)
- If the cooling fan is off, inspect for the following:
- Short to GND circuit between refrigerant pressure switch and PCM terminal 41
- DTC for ECT sensor (P0117, P0118, P0125)
9. Start the engine.
10. Verify that the cooling fan is operating when engine is hot.
- If the cooling fan does not operate, go to the next step.
11. Connect the SSTs (NGS tester) to the DLC-2.
12. Select the SIMULATION TEST function on the NGS display.
13. Select IG ON TEST mode.
14. Select FAN 3 PID.
15. Press START.
16. Verify that the cooling fan is operating.
- If the cooling fan operates, inspect the ECT sensor DTCs. (P0117, P0118, P0125).
- If the cooling fan does not operate, go to the next step.
17. Select FAN 3 PID.
18. Operate cooling fan by selecting START.
19. Verify that operation sound is heard from the cooling fan relay.
- If the operation sound is heard, inspect the wiring harness, connectors and cooling fan motor.
- If the operation sound is not heard, inspect cooling fan relay and open circuit in wiring harness and connectors.
20. Turn the A/C switch and fan switch on.
21. Verify that the cooling fan is operating.
22. If the fan does not operate, inspect A/C system.