Fuel Pump Relay: Testing and Inspection
FUEL PUMP RELAY (FP RLY) INSPECTIONNOTE: The lock of the FP RLY will be easily broken when removing the relay from the bracket. Do not remove the relay from the bracket except when replacement is required. Perform this "FUEL PUMP RELAY (FP RLY) INSPECTION" before removing the relay.
Simulation Test
1. Carry out the "Fuel Pump (FP) Operation Inspection", "Fuel Pump (FP) Control Inspection".
- If not as specified, perform the further inspection for the FP RLY.
Continuity Inspection
NOTE: Perform the following test only when directed.
1. Disconnect the negative battery cable.
2. Disconnect the FP RLY connector (6-pin type connector: 4 terminal) located above the AP.
3. Inspect for continuity between the FP RLY terminals using an ohmmeter.
- If not as specified, replace the FP RLY
- If as specified but the Simulation Test is tailed, perform the "Circuit Open/Short Inspection".
4. Connect the FP RLY connector.
5. Connect the negative battery cable.
Circuit Open/Short Inspection
Open circuit
- If there is no continuity, the circuit is open. Repair or replace the harness.
- GND circuit (FP RLY connector terminal B and PCM connector terminal 2M)
- GND circuit (FP RLY connector terminal C and FP connector terminal B through common connector)
- Power circuit (FP RLY connector terminal A or E and main relay connector terminal D)
Short circuit
- If there is continuity, the circuit is shorted. Repair or replace the harness.
- FP RLY connector terminal B and PCM connector terminal 2M to GND
- FP RLY connector terminal C and FP connector terminal B to GND