Automatic Transmission
Inspection of Operation1. Verify that the starter operates only with the ignition switch at the START position and selector lever in the P/N position.
2. Verify that the back-up lights illuminate when shifted to the R position with the ignition switch at the ON position.
^ If not as specified, inspect the continuity of the TR switch.
Inspection of Continuity
1. Inspect the OBD trouble code.
2. Remove the TR switch.
1 of 2
2 of 2
3. Inspect for continuity at the TR switch.
^ If not as specified, replace the TR switch.
4. Install the TR switch.