Variable Induction System: Testing and Inspection
1. Connect the WDS or equivalent to the DLC-2.2. Access ECT PID.
3. Verify ECT PID is 65 °C (149 °F) or less.
4. Start the engine.
5. Verify that the rod of tumble swirl control actuator is pulled.
- If the rod is not pulled, inspect the following.
- VTCS shutter valve actuator
- VTCS delay valve
- VTCS chamber
- Vacuum hose
- Tumble swirl control solenoid valve
- Wiring harness and connectors (Main relay - VTCS solenoid valve - PCM terminal 19)
6. Access RPM PID.
7. Inspect the rod operation under the following condition.
- If the rod operation is not as specified, inspect the following:
- Tumble swirl control actuator
- Vacuum delay valve
- Vacuum chamber
- Vacuum hose
- VTCS solenoid valve
- Wiring harness and connectors (Main relay - VTCS solenoid valve - PCM terminal 19)